Đến nội dung

KOREOS QUALITY VISION · Màn hình & chức năng

Camera, mm scale and 4-point calibration

Zoom, inspection area, mm scale and 4-point calibration for measuring.

Cập nhật Phiên bản hiện tại KOREOS QUALITY VISION 1.4.0Web · Android

Bài viết này chưa được dịch sang ngôn ngữ của bạn: đang hiển thị bản English.

Trong trang này

Adjust the camera

Camera button at the top of the station (Administrator and Quality only). While the panel is open the station shows the image but does not judge. Set zoom, resolution, focus and exposure (when the camera allows) and drag the inspection area (the square); then “Save to station”. The area is saved per part.

mm scale

Measure the real width of the square with a ruler, type it in mm and tap “Calibrate scale”: the area and finding sizes show in mm. Changed zoom or resolution? Calibrate again.

4-point calibration (measuring)

4-point calibration for measuring (demo part)
4-point calibration for measuring (demo part)

For measured parts: show the calibration target and tap “Lock” → tap the four corners in order top-left, top-right, bottom-right, bottom-left → tap both ends of a known dimension → Save. A quality score and check error are shown; the calibration is “ready” once it passes the limits. Parts with top and side views are calibrated in each view.

Trang này có hữu ích không?